Re: import from Hollis DG03
You can find the answer in the libdivecomputer FAQ.
- Fri Apr 04, 2014 06:10
- Forum: Allgemeines
- Topic: Nemo Wide kein Import von Temp. Nitrox, CNS
- Replies: 7
- Views: 8515
Re: Nemo Wide kein Import von Temp. Nitrox, CNS
Wasserart wird von libdivecomputer leider nicht unterstützt. Libdivecomputer does support retrieving the salinity setting nowadays (and atmospheric pressure too). Look for DC_FIELD_SALINITY. It will give you the water type (fresh or salt), and optionally the density if the device supports it. The o...
- Thu Mar 27, 2014 07:55
- Forum: Allgemeines
- Topic: Downloader: Fehlende Daten beim Oceanic OCi
- Replies: 1
- Views: 3033
Re: Downloader: Fehlende Daten beim Oceanic OCi
Most of the missing info you are referring too is not supported by the libdivecomputer parser. Unfortunately, that's a trade-off I have to make. In order to support many dive computers in a generic way, libdivecomputer can't support most of the device specific information. Even things that don't loo...
- Mon Mar 24, 2014 15:23
- Forum: General
- Topic: Suunto Vyper Air O2 Per Cent
- Replies: 4
- Views: 4222
Re: Suunto Vyper Air O2 Per Cent
For the bugfix, I made the assumption that the initial gas mix is always the first gas mix in the list of configured gas mixes. I don't know if the dive computer allows you to set another mix as the initial gas, but if it does, than it will still give you the wrong result. In that case I'll need a m...
- Mon Mar 24, 2014 07:39
- Forum: General
- Topic: Suunto Vyper Air O2 Per Cent
- Replies: 4
- Views: 4222
Re: Suunto Vyper Air O2 Per Cent
Does this happen for dives with or without gas switches? The libdivecomputer parser (used in the universal downloader) had a bug because it did not report the initial gas mix, which means that until the first gas switch occurs, the application doesn't know which gas mix is in use. The problem you ar...
- Sun Mar 09, 2014 07:36
- Forum: Allgemeines
- Topic: Cressi Leonardo - Import Daten vom Tauchcomputer
- Replies: 5
- Views: 7903
Re: Cressi Leonardo - Import Daten vom Tauchcomputer
See this topic for instructions on how to report problems.
- Tue Mar 04, 2014 15:45
- Forum: General
- Topic: Dive Rite NiTek Q (Full Trimix)
- Replies: 30
- Views: 48799
Re: Dive Rite NiTek Q (Full Trimix)
See one of my earlier replies for the instructions.
- Tue Mar 04, 2014 15:30
- Forum: General
- Topic: Dive Rite NiTek Q (Full Trimix)
- Replies: 30
- Views: 48799
Re: Dive Rite NiTek Q (Full Trimix)
My email address is on the libdivecomputer website: http://www.libdivecomputer.org/contact.html#personal
- Mon Mar 03, 2014 07:56
- Forum: General
- Topic: Dive Rite NiTek Q (Full Trimix)
- Replies: 30
- Views: 48799
Re: Dive Rite NiTek Q (Full Trimix)
The Nitek Q is supported in libdivecomputer now. It should be available from Diving Log with the next update. In the meantime, you can already download the latest dll from the libdivecomputer website, drop it into the Diving Log installation directory (keep a backup of the old dll, just in case), an...
- Fri Feb 21, 2014 07:46
- Forum: Extensions
- Topic: How to report dive computer download problems?
- Replies: 30
- Views: 109853
Re: How to report dive computer download problems?
Follow the instructions in the first post of this topic. I need that logfile to be able to see what is going wrong. For the Hollis DG03, you need the atom2 test application. Alternatively, you can generate the logfile directly from the Diving Log. Simply enable the "Log errors" checkbox, a...
- Wed Feb 19, 2014 07:21
- Forum: General
- Topic: Aeris Elite T3 wont connect
- Replies: 3
- Views: 3978
Re: Aeris Elite T3 wont connect
This error usually means another application already has the serial port open. Because serial ports are always openened with exclusive access mode on windows, only one application can use the serial port. Try to find which application has the port open (the Aeris application maybe?) and close it fir...
- Wed Feb 19, 2014 07:12
- Forum: General
- Topic: TUSA IQ-700 Download
- Replies: 3
- Views: 3842
Re: TUSA IQ-700 Download
The Apeks Quantum X and Dive Rite NiTek Trio are already supported through the n2ition3 backend. Maybe the NiTek Duo is compatible with that backend instead? If not, you'll have to capture the communication as described on the libdivecomputer website. You'll need a 32bit Windows setup (inside a virt...
- Tue Feb 11, 2014 12:20
- Forum: Allgemeines
- Topic: Fehler bei bluetooth - shearwater
- Replies: 3
- Views: 4489
Re: Fehler bei bluetooth - shearwater
The error "Zugriff verweigert" usually means there is some other application that has already opened the serial port. Only one application can open a serial port at the same time. Check for example if there is no application that is trying to use the serial port as a modem.
- Tue Feb 11, 2014 12:18
- Forum: General
- Topic: Gases incorrectly imported from Suunto HelO2
- Replies: 2
- Views: 2777
Re: Gases incorrectly imported from Suunto HelO2
Are you using the Suunto downloader or the universal downloader? If you're using the universal downloader, then have a look at this topic for how to report problems. You'll need the vyper2 test application for the Suunto Helo2.
- Wed Jan 29, 2014 10:37
- Forum: General
- Topic: Problem to download from Subgear xp-h
- Replies: 3
- Views: 4042
Re: Problem to download from Subgear xp-h
Can you enable the "Log errors" checkbox, and then when the download fails, click the "Show error logfile" link to open the error log? Then send me this file. You can find my email address on the libdivecomputer website. If the logfile is short, you can also just paste the ouput ...