Search found 255 matches

by TnT
Mon Aug 04, 2014 07:11
Forum: Extensions
Topic: elite t3.
Replies: 2
Views: 5698

Re: elite t3.

When running the atom2 test application you need to pass the correct serial port as the only argument. If you start it by double clicking, then it will use COM1 as the default, which is usually not the correct port for usb-serial cables. If you're not familiar with command line applications, the eas...
by TnT
Tue Jul 15, 2014 06:08
Forum: Allgemeines
Topic: Profil falsch
Replies: 22
Views: 9044

Re: Profil falsch

Sven, if I compare the first two screenshots, then the entire profile is shifted down by a few meters. You can clearly see this at the start and end of the dive. That makes me think there might be some problem with the initial depth calibration sample. @God-of-Games: Can you also try downloading wit...
by TnT
Mon Jun 23, 2014 08:32
Forum: General
Topic: Aeris T3 Elite
Replies: 1
Views: 1072

Re: Aeris T3 Elite

See this topic: viewtopic.php?f=10&t=1296. For the Aeris T3 Elite you'll need the atom2 test application.
by TnT
Sat Jun 21, 2014 17:22
Forum: Allgemeines
Topic: Downloader Fehler mit Mares Puck
Replies: 6
Views: 3463

Re: Downloader Fehler mit Mares Puck

It looks like a crash in the libdivecomputr parser. Can you send me a memory dump of your device? Download the universal test application, and run it with these options: universal.exe -v -l iconhd.log -m iconhd.bin -b iconhd <serialport> Replace <serialport> with the correct serial port, the same as...
by TnT
Mon Jun 16, 2014 12:49
Forum: Extensions
Topic: Computer download problem for Mares Icon HD (net ready)
Replies: 1
Views: 5696

Re: Computer download problem for Mares Icon HD (net ready)

It's possible that the deco info isn't recorded by the dive computer, but calculated by the Mares application on the fly.
by TnT
Mon Jun 16, 2014 12:46
Forum: Allgemeines
Topic: Downloader Fehler mit Mares Puck
Replies: 6
Views: 3463

Re: Downloader Fehler mit Mares Puck

Can you copy and past the details of the exception?

BTW, if the download works with "Puck Pro" and not "Puck", that means you have a Puck Pro and not a normal Puck. Despite the similar name, these are two very different devices.
by TnT
Fri May 30, 2014 06:15
Forum: Allgemeines
Topic: Mares Airlab
Replies: 1
Views: 1524

Re: Mares Airlab

As far as I know the Mares Airlab is identical to the Darwin Airlab (e.g a rebranded version). So downloading as Darwin Airlab should work fine. If you send me a memory dump of your dive computer, I can double check. See this topic for instructions. You need the "darwin" test application. What exact...
by TnT
Fri May 30, 2014 06:06
Forum: General
Topic: importing gas data suunto vyper
Replies: 9
Views: 3231

Re: importing gas data suunto vyper

If you send me a memory dump of your dive computer, I'll have a look at the 02 percentages. See this topic for instructions.
by TnT
Tue May 06, 2014 09:02
Forum: General
Topic: import from Hollis DG03
Replies: 2
Views: 1545

Re: import from Hollis DG03

You can find the answer in the libdivecomputer FAQ.
by TnT
Fri Apr 04, 2014 06:10
Forum: Allgemeines
Topic: Nemo Wide kein Import von Temp. Nitrox, CNS
Replies: 7
Views: 3094

Re: Nemo Wide kein Import von Temp. Nitrox, CNS

Wasserart wird von libdivecomputer leider nicht unterstützt. Libdivecomputer does support retrieving the salinity setting nowadays (and atmospheric pressure too). Look for DC_FIELD_SALINITY. It will give you the water type (fresh or salt), and optionally the density if the device supports it. The o...
by TnT
Thu Mar 27, 2014 07:55
Forum: Allgemeines
Topic: Downloader: Fehlende Daten beim Oceanic OCi
Replies: 1
Views: 1325

Re: Downloader: Fehlende Daten beim Oceanic OCi

Most of the missing info you are referring too is not supported by the libdivecomputer parser. Unfortunately, that's a trade-off I have to make. In order to support many dive computers in a generic way, libdivecomputer can't support most of the device specific information. Even things that don't loo...
by TnT
Mon Mar 24, 2014 15:23
Forum: General
Topic: Suunto Vyper Air O2 Per Cent
Replies: 4
Views: 1881

Re: Suunto Vyper Air O2 Per Cent

For the bugfix, I made the assumption that the initial gas mix is always the first gas mix in the list of configured gas mixes. I don't know if the dive computer allows you to set another mix as the initial gas, but if it does, than it will still give you the wrong result. In that case I'll need a m...
by TnT
Mon Mar 24, 2014 07:39
Forum: General
Topic: Suunto Vyper Air O2 Per Cent
Replies: 4
Views: 1881

Re: Suunto Vyper Air O2 Per Cent

Does this happen for dives with or without gas switches? The libdivecomputer parser (used in the universal downloader) had a bug because it did not report the initial gas mix, which means that until the first gas switch occurs, the application doesn't know which gas mix is in use. The problem you ar...
by TnT
Sun Mar 09, 2014 07:36
Forum: Allgemeines
Topic: Cressi Leonardo - Import Daten vom Tauchcomputer
Replies: 5
Views: 4212

Re: Cressi Leonardo - Import Daten vom Tauchcomputer

See this topic for instructions on how to report problems.
by TnT
Tue Mar 04, 2014 15:45
Forum: General
Topic: Dive Rite NiTek Q (Full Trimix)
Replies: 30
Views: 28933

Re: Dive Rite NiTek Q (Full Trimix)

See one of my earlier replies for the instructions.