Search found 254 matches

by TnT
Mon Jun 29, 2015 19:34
Forum: General
Topic: lost temperature profile
Replies: 3
Views: 1791

Re: lost temperature profile

However it would be better to find the root of this issue. I have to ask Jef, but if I remember right, the Vyper does not record a full temperature profile, but only records temperature at start, end and lowest temperature. Libdivecomputer and Suunto DM create a fake temperature profile from it, wh...
by TnT
Thu Jun 11, 2015 06:31
Forum: Allgemeines
Topic: Oceanic VTX / Aeris A300
Replies: 3
Views: 2076

Re: Oceanic VTX / Aeris A300

Enable the "Log errors" checkbox, and then when the download fails, click the "Show error logfile" link to open the error log. Send this logfile by email, or if it's short you can post it directly on the forum.
by TnT
Fri Mar 27, 2015 13:49
Forum: Extensions
Topic: Can not connect Suunto Eon Steel
Replies: 15
Views: 14071

Re: Can not connect Suunto Eon Steel

That assertion should only be triggered if there is a bug in the code. Are you trying to download from a device without any dives yet? I've build a version with the assert disabled. Drop it into the divinglog installation directory (backup the existing dll), and try again. http://libdivecomputer.org...
by TnT
Wed Mar 25, 2015 07:33
Forum: Extensions
Topic: Can not connect Suunto Eon Steel
Replies: 15
Views: 14071

Re: Can not connect Suunto Eon Steel

As far as I know, nobody has ever tested the Eon Steel on Windows using libdivecomputer before. Libdivecomputer uses the libusb library for the USB communication. This requires the winusb driver to be installed for the device. My guess is that this driver isn't installed. There is simple tool named ...
by TnT
Wed Mar 25, 2015 07:13
Forum: Allgemeines
Topic: Direktes auslesen von Hollis Explorer
Replies: 4
Views: 2454

Re: Direktes auslesen von Hollis Explorer

If you're lucky, then the Hollis Explorer uses the same protocol as the other Hollis/Oceanic dive computers. To check this, download the universal test application, and run it with these options: universal.exe -v -l atom2.log -m atom2.bin -b atom2 <COMx> Replace <COMx> with the correct serial port (...
by TnT
Sat Feb 14, 2015 08:47
Forum: General
Topic: Download problems!
Replies: 11
Views: 4247

Re: Download problems!

The usb-serial chip is in the pc interface, not your brand new PC. If the cable worked fine before on an older PC, then most likely you had an older driver installed. And when moving to a new system, you installed the latest version, which happens to have that counterfeit check added. Note that thes...
by TnT
Fri Feb 13, 2015 21:00
Forum: General
Topic: Download problems!
Replies: 11
Views: 4247

Re: Download problems!

The exlamation mark icon indicates the driver failed to load. That's why COM5 doesn't show up. You might be affected by the counterfeit chip detection that Prolific added to their driver. If that's the case, you'll need to find an old driver: http://wp.brodzinski.net/hardware/fake-pl2303-how-to-inst...
by TnT
Fri Feb 13, 2015 15:00
Forum: General
Topic: Download problems!
Replies: 11
Views: 4247

Re: Download problems!

Can you post a screenshot of the device manager?
by TnT
Thu Feb 12, 2015 07:17
Forum: General
Topic: Download problems!
Replies: 11
Views: 4247

Re: Download problems!

Did you install the driver?
by TnT
Mon Feb 02, 2015 07:40
Forum: Allgemeines
Topic: DC_STATUS_PROTOCOL Suunto Gekko
Replies: 2
Views: 1878

Re: DC_STATUS_PROTOCOL Suunto Gekko

INFO: Read: size=33, data=00000505807DFCFD01FEFDFF4000FFFFFF00FF000100000000010000000000FFD6 ERROR: Unexpected answer checksum. [in suunto_vyper.c:387 (suunto_vyper_read_dive)] ERROR: Das Handle ist ungültig (6) [in serial_win32.c:187 (serial_close)] This is most likely a sign that the connection g...
by TnT
Mon Dec 01, 2014 22:15
Forum: General
Topic: missing data
Replies: 6
Views: 3459

Re: missing data

The libdivecomputer backends for the newer Suunto's (d9 and vyper2) already support ndl/deco info. But it's limited in functionality because they only indicate whether a sample is ndl or deco. There is no ndl/deco time or stop depth info present. I'll have to ask Sven whether this feature is already...
by TnT
Tue Sep 16, 2014 06:58
Forum: General
Topic: Niteq Q beginner
Replies: 5
Views: 2106

Re: Niteq Q beginner

The information recorded by the Nitek Q is indeed very basic, but gas switch events are available.
by TnT
Thu Sep 11, 2014 07:36
Forum: General
Topic: Problem with downloader and Suunto
Replies: 1
Views: 1374

Re: Problem with downloader and Suunto

I checked the COM port (it was unique and not in use by another device), and also tried to change the COM port, but still no access. Reading from my backup computer Mares Puck works with the same port. For usb-serial devices, COM ports are assigned dynamically. Usually the same device always gets t...
by TnT
Wed Aug 20, 2014 10:00
Forum: General
Topic: missing data
Replies: 6
Views: 3459

Re: missing data

The oceanic backends still do not have deco/ndl support. Reverse engineering the data is very time consuming, especially for the oceanics because each model uses a slightly different data format.
by TnT
Mon Aug 04, 2014 07:11
Forum: Extensions
Topic: elite t3.
Replies: 2
Views: 5478

Re: elite t3.

When running the atom2 test application you need to pass the correct serial port as the only argument. If you start it by double clicking, then it will use COM1 as the default, which is usually not the correct port for usb-serial cables. If you're not familiar with command line applications, the eas...