Search found 257 matches

by TnT
Mon Oct 12, 2015 07:27
Forum: General
Topic: Tusa Zen IQ-900 Import Issue
Replies: 13
Views: 5984

Re: Tusa Zen IQ-900 Import Issue

I'll need a memory dump of your dive computer to investigate this. Download the universal test application, and run it with these options: universal.exe -v -l atom2.log -m atom2.bin -b atom2 <COMx> Replace <COMx> with the correct serial port (typically COM3). Afterwards, email me the atom2.log and a...
by TnT
Wed Aug 05, 2015 05:56
Forum: General
Topic: Trouble Downloading from Suunto Cobra
Replies: 11
Views: 4537

Re: Trouble Downloading from Suunto Cobra

The "Access is denied" error usually indicates some other application already has the serial port open. Do you have Suunto DM running at the same time?
by TnT
Sun Aug 02, 2015 19:45
Forum: General
Topic: Profile not showing gas mixes
Replies: 9
Views: 5287

Re: Profile not showing gas mixes

Multiple gas mixes and gas switches are fully supported for the Vytec. This has been implemented long time ago. So I'm not sure why they are not showing up for you. The only outstanding issue is that a switch to an identical gas mix (e.g. Air to Air) won't be detected. But that does not apply to you...
by TnT
Mon Jun 29, 2015 19:34
Forum: General
Topic: lost temperature profile
Replies: 3
Views: 1980

Re: lost temperature profile

However it would be better to find the root of this issue. I have to ask Jef, but if I remember right, the Vyper does not record a full temperature profile, but only records temperature at start, end and lowest temperature. Libdivecomputer and Suunto DM create a fake temperature profile from it, wh...
by TnT
Thu Jun 11, 2015 06:31
Forum: Allgemeines
Topic: Oceanic VTX / Aeris A300
Replies: 3
Views: 2266

Re: Oceanic VTX / Aeris A300

Enable the "Log errors" checkbox, and then when the download fails, click the "Show error logfile" link to open the error log. Send this logfile by email, or if it's short you can post it directly on the forum.
by TnT
Fri Mar 27, 2015 13:49
Forum: Extensions
Topic: Can not connect Suunto Eon Steel
Replies: 15
Views: 15258

Re: Can not connect Suunto Eon Steel

That assertion should only be triggered if there is a bug in the code. Are you trying to download from a device without any dives yet? I've build a version with the assert disabled. Drop it into the divinglog installation directory (backup the existing dll), and try again. http://libdivecomputer.org...
by TnT
Wed Mar 25, 2015 07:33
Forum: Extensions
Topic: Can not connect Suunto Eon Steel
Replies: 15
Views: 15258

Re: Can not connect Suunto Eon Steel

As far as I know, nobody has ever tested the Eon Steel on Windows using libdivecomputer before. Libdivecomputer uses the libusb library for the USB communication. This requires the winusb driver to be installed for the device. My guess is that this driver isn't installed. There is simple tool named ...
by TnT
Wed Mar 25, 2015 07:13
Forum: Allgemeines
Topic: Direktes auslesen von Hollis Explorer
Replies: 4
Views: 2664

Re: Direktes auslesen von Hollis Explorer

If you're lucky, then the Hollis Explorer uses the same protocol as the other Hollis/Oceanic dive computers. To check this, download the universal test application, and run it with these options: universal.exe -v -l atom2.log -m atom2.bin -b atom2 <COMx> Replace <COMx> with the correct serial port (...
by TnT
Sat Feb 14, 2015 08:47
Forum: General
Topic: Download problems!
Replies: 11
Views: 4626

Re: Download problems!

The usb-serial chip is in the pc interface, not your brand new PC. If the cable worked fine before on an older PC, then most likely you had an older driver installed. And when moving to a new system, you installed the latest version, which happens to have that counterfeit check added. Note that thes...
by TnT
Fri Feb 13, 2015 21:00
Forum: General
Topic: Download problems!
Replies: 11
Views: 4626

Re: Download problems!

The exlamation mark icon indicates the driver failed to load. That's why COM5 doesn't show up. You might be affected by the counterfeit chip detection that Prolific added to their driver. If that's the case, you'll need to find an old driver: http://wp.brodzinski.net/hardware/fake-pl2303-how-to-inst...
by TnT
Fri Feb 13, 2015 15:00
Forum: General
Topic: Download problems!
Replies: 11
Views: 4626

Re: Download problems!

Can you post a screenshot of the device manager?
by TnT
Thu Feb 12, 2015 07:17
Forum: General
Topic: Download problems!
Replies: 11
Views: 4626

Re: Download problems!

Did you install the driver?
by TnT
Mon Feb 02, 2015 07:40
Forum: Allgemeines
Topic: DC_STATUS_PROTOCOL Suunto Gekko
Replies: 2
Views: 2049

Re: DC_STATUS_PROTOCOL Suunto Gekko

INFO: Read: size=33, data=00000505807DFCFD01FEFDFF4000FFFFFF00FF000100000000010000000000FFD6 ERROR: Unexpected answer checksum. [in suunto_vyper.c:387 (suunto_vyper_read_dive)] ERROR: Das Handle ist ungültig (6) [in serial_win32.c:187 (serial_close)] This is most likely a sign that the connection g...
by TnT
Mon Dec 01, 2014 22:15
Forum: General
Topic: missing data
Replies: 6
Views: 3767

Re: missing data

The libdivecomputer backends for the newer Suunto's (d9 and vyper2) already support ndl/deco info. But it's limited in functionality because they only indicate whether a sample is ndl or deco. There is no ndl/deco time or stop depth info present. I'll have to ask Sven whether this feature is already...
by TnT
Tue Sep 16, 2014 06:58
Forum: General
Topic: Niteq Q beginner
Replies: 5
Views: 2304

Re: Niteq Q beginner

The information recorded by the Nitek Q is indeed very basic, but gas switch events are available.