Search found 3 matches

by dboyer
Tue May 21, 2013 12:12
Forum: General
Topic: DC_STATUS_PROTOCOL error
Replies: 6
Views: 6593

Re: DC_STATUS_PROTOCOL error

Looks like the problem was the USB driver. I re-installed the USB download driver from the Oceanic website. It added a second COM port selection to the drop down list in the universal downloader. Chose it and now Diving Log works just fine.

Many thanks for the help!
by dboyer
Mon May 20, 2013 21:41
Forum: General
Topic: DC_STATUS_PROTOCOL error
Replies: 6
Views: 6593

Re: DC_STATUS_PROTOCOL error

Installed the beta and I'm still getting the error. Here is the error log: INFO: Configure: baudrate=38400, databits=8, parity=0, stopbits=1, flowcontrol=0 INFO: Timeout: value=3000 INFO: Sleep: value=100 INFO: Flush: queue=3, input=0, output=0 INFO: Write: size=2, data=8400 INFO: Read: size=1, data...
by dboyer
Mon May 20, 2013 11:39
Forum: General
Topic: DC_STATUS_PROTOCOL error
Replies: 6
Views: 6593

DC_STATUS_PROTOCOL error

I am a long time Diving Log user and this is the first time I've ever had an issue that required support. I'm trying to download dives from my 2 Oceanic VEO 3.0 computers and getting a DC_STATUS_PROTOCOL error. Some background info: I used Diving Log on a Windows 7 laptop for a long time and it work...