With the latest update, it appears that the gas % mix is no longer on the default main log page. Also noticed that the GAS tab is missing from the ADDITIONAL section. Do we need to manually add those back in?
Jim
Search found 28 matches
- Sun May 21, 2023 20:47
- Forum: General
- Topic: Lost Gas Mix Fields
- Replies: 1
- Views: 8280
- Sun May 21, 2023 20:44
- Forum: General
- Topic: SfGF Tracking
- Replies: 2
- Views: 7863
Re: SfGF Tracking
Thanks Sven! Just keep up the good work on the app.
- Wed May 03, 2023 00:33
- Forum: General
- Topic: PpO2 sensor info not available anymore
- Replies: 10
- Views: 12200
Re: PpO2 sensor info not available anymore
Likewise, also been looking for this feature. I'd just like to see the mV reading across the dive.
- Sun Apr 23, 2023 17:06
- Forum: General
- Topic: SfGF Tracking
- Replies: 2
- Views: 7863
SfGF Tracking
I see a recent update where TTS may soon be available via divlib, but is SgGF also available?
- Sun Apr 23, 2023 17:01
- Forum: General
- Topic: PpO2 sensor info not available anymore
- Replies: 10
- Views: 12200
Re: PpO2 sensor info not available anymore
Older thread, but are the PPO2 values available directly via download from the SW computer, or do I need go pull those in via Shearwater Cloud?
- Sun Sep 15, 2019 14:36
- Forum: Extensions
- Topic: Unable to get O2 cell data after update
- Replies: 14
- Views: 28264
Re: Unable to get O2 cell data after update
For CCR, it looks like Profile 5 shows PPO2 for three cells, but from a previous post, it seems to need the calibration constant which is applied to Milli-volts to calculate PPo2? So in reality we can't get either PPOs or Mv imported from the Shearwater? Are there any plans to at least capture mV re...
- Fri Aug 16, 2019 04:20
- Forum: Extensions
- Topic: Unable to get O2 cell data after update
- Replies: 14
- Views: 28264
Re: Unable to get O2 cell data after update
Is it possible to just display the mV data instead of the PO2 (assuming the calibration value is missing). I'm not finding that data available in the log.
- Fri Jan 18, 2019 02:18
- Forum: General
- Topic: PPO2 Values Missing
- Replies: 3
- Views: 4390
Re: PPO2 Values Missing
So I'm guessing that the only solution is to sync with Shearwater Desktop, then import those dives to DL? Per SW Desktop, we can see the three O2 sensor values, and the average PPO2 in the graph. I'd think for CCR, it's interesting to have this data from any unit, and with Shearwater Divecan getting...
- Tue Jan 15, 2019 04:46
- Forum: General
- Topic: PPO2 Values Missing
- Replies: 3
- Views: 4390
PPO2 Values Missing
I see some older threads on missing PPO2 values, but I'm curious if this has a fix. It looks like my Petral 2 has imported Setpoints, but the Profile 5 PO-1 -> PO-3 values are all 0. Looking at the Shearwater desktop, I do see mV values being recorded for each sensor. I've been able to import the di...
- Tue Jan 15, 2019 04:06
- Forum: General
- Topic: Petral 2 CCR - > PC Sync
- Replies: 1
- Views: 3004
Re: Petral 2 CCR - > PC Sync
Solved the issue. After the Petral Synched with the Shearwater Desktop, I found that the new Petral needed a new OUTGOING Serial, so after adding a new and additional OUTGOING port, it synched.
- Mon Jan 14, 2019 01:16
- Forum: General
- Topic: Petral 2 CCR - > PC Sync
- Replies: 1
- Views: 3004
Petral 2 CCR - > PC Sync
I've had a Petral 2 I've been using for OC diving and I've been able to sync (although it's temperamental) on a Win10 machine. I'm trying to sync a Hollis branded Petral 2 used for CCR and am unable to sync. I've tried re-pairing, I've made sure I have both inbound and outbound COM ports, it appears...
- Sun Apr 22, 2018 15:48
- Forum: Android, iPhone & iPad
- Topic: Feature Request - Equipment Configuration
- Replies: 2
- Views: 6009
Feature Request - Equipment Configuration
I tend to dive the same configurations with only minor variations. Is it possible to set several different equipment configurations to quickly enter all the equipment (cold water, warm water, tank config, camera/no camera)?
Thanks!
Jim
Thanks!
Jim
- Mon Apr 16, 2018 02:02
- Forum: General
- Topic: Shearwater Cloud
- Replies: 1
- Views: 2982
Shearwater Cloud
I thought I remember the release notes for 6.0.13 saying that there was import support for Shearwater Cloud, however I don't see that option for the Importer, only Desktop. Am I wrong here?
- Sun Jul 05, 2015 18:16
- Forum: General
- Topic: Petrel BT import problems
- Replies: 9
- Views: 18702
Re: Petrel BT import problems
Got it figured out. Running Petrel 2, connected via BT to Win 8.2 laptop. Under BT settings, it had assigned a COM4 for the Petrel, but was listed as INCOMING. Once I manually created a virtual COM3, OUTGOING port for the Petrel, it synched up nicely. No more Shearwater software transfers!
- Sat Jul 04, 2015 21:48
- Forum: General
- Topic: Petrel BT import problems
- Replies: 9
- Views: 18702
Re: Petrel BT import problems
I'm running into the same issue with the Petral 2. I see a COM4 port, as mentioned previous, I'm not getting a download. I've tried running DiveLog as admin, but that didn't seem to help.